Discharge temperature: 20±2℃ | |||||
Discharge condition | GB/T8897.2-2008 national standard requirements | Minimum average discharge time | |||
Discharge load | Discharge method | End voltage |
New electricity within 2 months | 12 months storage at room temperature | |
6.8Ω | 1h/d | 0.9 V | 9h | 10h | 9h |
20Ω | 4h/d | 0.9 V | 27h | 32h | 28h |
3.9Ω | 4m/h,8h/d | 0.9 v | 270min | 300min | 270min |
3.9Ω | 1h/d | 0.8 V | 3h | 5.5h | 4.9h |
3.9Ω | 24h/d | 0.9 V | / | 4.5h | 4h |
With product technical updates and technical parameter adjustments, the specifications will be updated at any time, please contact Anida in time to obtain the latest version of the specifications.
Typical discharge curve Discharge environment: 20℃±2℃, RH60±15%Overview This specification stipulates the technical requirements of Anida R14P carbon zinc manganese dry battery. If other detailed requirements are not listed, the battery technical requirements and dimensions should meet or exceed GB/T8897.1 and GB/T8897.2. 1.1 Reference Standard GB/T8897.1 (IEC60086-1, MOD) (Primary Battery Part 1: General Provisions) GB/T8897.2 (IEC60086-2, MOD) (Primary battery Part 2: Dimensions and technical requirements) GB8897.5 (IEC 60086-5, MOD) (Primary battery Part 5: Safety requirements for aqueous electrolyte batteries) 1.2 Environmental standards The battery complies with EU 2006/66/EC battery directiveElectrochemical system, voltage and naming Electrochemical system: zinc-manganese dioxide (ammonium chloride electrolyte solution), no mercury Nominal voltage: 1.5V Designation: IEC: R14P ANSI: C JIS: SUM-2 Others: 14FBattery size The battery meets the requirements of the sketch 3.1 Acceptance tools Use a vernier caliper with an accuracy of not less than 0.02mm to prevent battery short circuit during measurement. One end of the caliper should be pasted with a layer of insulating material. 3.2 Acceptance method Adopt GB2828.1-2003 normal inspection one-time sampling plan, special inspection level S-3, acceptance quality limit AQL=1.0 project | Open circuit voltage OCV (V) | Load voltage CCV (V) | Short circuit current SCC (A) | Sampling standard |
New electricity within 2 months | 1.60 | 1.40 | 5.0 | GB2828.1-2003 One-time sampling plan for normal inspection, special inspection level S-4, AQL=1.0 |
12 months storage at room temperature | 1.56 | 1.35 | 4.00 | |
Test Conditions | Load resistance 3.9Ω, load time 0.3 seconds, test temperature 20±2℃ |
project | condition | Claim | Eligibility criteria |
Overdischarge | Under the condition of 20±2℃ and humidity 60±15%, the load resistance is 3.9Ω. Discharge for 1 hour per day to 0.6V termination |
No leakage by visual inspection | N=9 Ac=0 Re=1 |
High temperature storage | Store at 45±2℃, relative humidity 90%RH for 20 days |
| N=30 Ac=1 Re=2 |
project | condition | Claim | Eligibility criteria |
External short circuit | At 20±2℃, connect the positive and negative poles of the battery with wires and leave it for 24 hours | Does not explode | N=5 Ac=0 Re=1 |