temperature: 20±2℃ | |||||
Discharge Conditions | GB/T8897.2 National standard requirement | Shortest Average Discharging Time | |||
Discharge load | Discharge Time | Cut-off discharge voltage |
| 2 months, new battery | After 12 months at room temperature |
10Ω | 1h/d | 0.9 V | 1.5h | 2.4h | 2.1h |
75Ω | 4h/d | 0.9 V | 20h | 21h | 20h |
5.1Ω | 4m/h,8h/d | 0.9 V | 50min | 70min | 65min |
24Ω | 15s/m,8h/d | 1.0 V | 4h | 5.5h | 5h |
3.9Ω | 24h/d | 0.9 V | / | 35min | 32min |
With parameter adjustment, product technology updates, technology specification will update at any time, please do not hesitate to contact to stand for the latest version of the specification.
Typical discharge curve Discharge environment: 20℃±2℃, RH60±15%Scope This specification governs the technical requirements of Sunmol Carbon Zinc battery of R03P/AAA. If it doesn’t list the other detailed requirements, the technical requirements and dimensions of battery should meet or above GB/T8897.1 and GB /T8897.2. 1.1Reference Document GB/T8897.1 (IEC60086-1, MOD)(Primary Battery Part 1: General) GB/T8897.2 (IEC60086-2, MOD)(Primary Battery Part 2: Dimensions and Technical Requirements) GB8897.5 (IEC 60086-5, MOD)(Primary Battery Part 5: aqueous electrolyte battery safety requirements) 1.2Environmental protection standard The battery accord with 2006/66/ECChemical system, Voltage and Designation Electrochemical system: zinc - manganese dioxide (ammonium chloride electrolyte solution), does not contain mercury Nominal voltage: 1.5V Naming: IEC: R03P ANSI: AAA JIS: SUM-4 Others: 24FBattery Size Conform to the requirements of the brief 3.1 Acceptance tool Using vernier caliper measurement precision is not less than 0.02 mm, measure to prevent the battery short circuit, one end of the caliper head card should be labeled as a layer of insulating materials. 3.2 Acceptance methods The GB2828.1-2003 normal inspection sampling plan at a time, special inspection level S-3, acceptance quality limit AQL=1.0 items | OCV(V) | CCV(V) | SCC(A) | sampling standard |
After 2 months, new battery | 1.62 | 1.40 | 2.50 | GB2828.1-2003 Normal inspection sampling plan, special inspection level S-4,AQL=1.0 |
After 12 months at room temperature | 1.58 | 1.30 | 2.00 | |
Test conditions | load resistance 3.9Ω, measuring time 0.3 seconds,temperature 20±2℃ |
items | Conditions | requirement | Acceptance Standard |
Over-discharge | at temperature 20±2; relative humidity: 60±15% RH, load 10Ω, Discharge one hour everyday until the voltage turn to 0.6V | No leakage recognized by eyes | N=9 Ac=0 Re=1 |
high temperature storage | Stored in 45±2℃, Under the environment of relative humidity to 90% RH for 20 days |
| N=30 Ac=1 Re=2 |
items | Condition | Requirement | Acceptance Standard |
External short circuit | At temperature 20±2℃, With wires to the battery positive negative switched on 24 hours | No explosion allowed | N=5 Ac=0 Re=1 |