temperature: 20±2℃ | |||||
Discharge Conditions | GB/T8897.2 National standard requirement | Shortest Average Discharging Time | |||
Discharge load | Discharge Time | Cut-off discharge voltage |
| 2 months, new battery | After 12 months at room temperature |
10Ω | 1h/d | 0.9 V | 1.5h | 2.4h | 2.1h |
75Ω | 4h/d | 0.9 V | 20h | 21h | 20h |
5.1Ω | 4m/h,8h/d | 0.9 V | 50min | 70min | 65min |
24Ω | 15s/m,8h/d | 1.0 V | 4h | 5.5h | 5h |
3.9Ω | 24h/d | 0.9 V | / | 35min | 32min |

With parameter adjustment, product technology updates, technology specification will update at any time, please do not hesitate to contact to stand for the latest version of the specification.
Typical discharge curve Discharge environment: 20℃±2℃, RH60±15%


items | OCV(V) | CCV(V) | SCC(A) | sampling standard |
After 2 months, new battery | 1.62 | 1.40 | 2.50 | GB2828.1-2003 Normal inspection sampling plan, special inspection level S-4,AQL=1.0 |
After 12 months at room temperature | 1.58 | 1.30 | 2.00 | |
Test conditions | load resistance 3.9Ω, measuring time 0.3 seconds,temperature 20±2℃ |
items | Conditions | requirement | Acceptance Standard |
Over-discharge | at temperature 20±2; relative humidity: 60±15% RH, load 10Ω, Discharge one hour everyday until the voltage turn to 0.6V | No leakage recognized by eyes | N=9 Ac=0 Re=1 |
high temperature storage | Stored in 45±2℃, Under the environment of relative humidity to 90% RH for 20 days |
| N=30 Ac=1 Re=2 |
items | Condition | Requirement | Acceptance Standard |
External short circuit | At temperature 20±2℃, With wires to the battery positive negative switched on 24 hours | No explosion allowed | N=5 Ac=0 Re=1 |